- Store
- >
- UV Systems For Bacteria & Viruses Removal
- >
- Viqua PRO-30 NSF 55 Class A Certified UV Light
Viqua PRO-30 NSF 55 Class A Certified UV Light
SKU:
$4,540.00
4240
4540
$4,240.00
$4,240.00
On Sale
Unavailable
per item
- NSF 55 Class A Certified Ultraviolet Disinfection System Rated @ 30gpm - Whole House or Light Commercial Bacteria and Virus Safe Water Treatment - Now Add A NSF Certified 5 Micron Sediment Pre-filter At No Extra Charge.
Ask About Our Current PRO-30 UV Online Specials Before Ordering
- UV Is Effective in killing off bacteria and viruses:
- Coliform Bacteria
- Leptospira Interrogans (Infectious Jaundice)
- Salmonella Typhosa (Typhoid Fever)
- Bacteriophage (E. coli)
- Hepatitus Virus
- Chlorella Vulgaris
- Influenza Virus
- Legionella Pneumophila (Legionnaires' Disease)
Exclusively From RainDance Water Systems:
- FREE Separate NSF Certified 5 Micron Sediment Pre-Filter
- Includes Pre-Loaded Flash Drive Containing UV Installation Instructions, Owners Manual, Diagrams & Parts List
Do You Require An NSF 55 Class A Certified UV System: UV Systems that are certified to NSF Standard 55 Class A are typically used in "public" drinking water facilities. This includes such facilities as restaurants, campgrounds, churches, offices, beverage and produce growers. NSF Standard 55 Class A certified UV systems are also used for small drinking water treatment plants and community wells. In some U.S. States and Canadian Provinces the local government has mandated that even private homes must use NSF Standard 55 Class A certified products wherever UV is chosen.
Class A Systems (minimum dose of 40 mJ/cm2 ) are designed for use on drinking water of unknown quality to disinfect and/or inactivate microorganisms, including bacteria and viruses, from contaminated water to a safe level. Class A systems may claim to disinfect water that may be contaminated with pathogenic bacteria, viruses, Cryptosporidium or Giardia. Class A systems must include alarms and a UV sensor to assure proper dosing and treatment.
You can have Peace-Of-Mind knowing that the PRO-30 UV is NSF /ANSI 55 Class A Certified- New: Add A NSF Certified 5 Micron Prefilter System At No Extra Charge!
Class A Systems (minimum dose of 40 mJ/cm2 ) are designed for use on drinking water of unknown quality to disinfect and/or inactivate microorganisms, including bacteria and viruses, from contaminated water to a safe level. Class A systems may claim to disinfect water that may be contaminated with pathogenic bacteria, viruses, Cryptosporidium or Giardia. Class A systems must include alarms and a UV sensor to assure proper dosing and treatment.
You can have Peace-Of-Mind knowing that the PRO-30 UV is NSF /ANSI 55 Class A Certified- New: Add A NSF Certified 5 Micron Prefilter System At No Extra Charge!
Viqua PRO-30 Features:
- NSF 55 Class A Certified for flow rates up to 30 gpm
- New, market leading flow-meter/UV sensor combination provides real-time UV dose
- UV Max PRO Series Models are NSF Certified & Include UV Intensity Monitor, Flow Restrictor, Timer, Alarm Reset, Lamp Life Display & Alert, Digital Display, Cooltouch Kit & Shut-off Valve as standard features
- All UV Max PRO Series Systems include all components and accessories needed for initial installation and use. These include UV Lamp, Power Supply, Quartz Sleeve & 316 Stainless Steel UV Reactor (Water Chamber).
OPTIONAL: COMMcenter – Demonstrates to regulators how system has been functioning over an extended period of time. Displays UV dose, alarm history, lamp hours and other performance parameters. With the introduction of the new flow meter on VIQUA PRO series systems, the COMMcenter now gives accurate dosage readings, per minute, in real time as flows change. Minute-by-minute data is logged permanently to the miniSD card, allowing easy reference through history for regulatory or troubleshooting purposes. Contact Us for details.
|
How Ultraviolet Disinfection System Works
As water flows past the UV lamp(s) in a UV disinfection system, microorganisms are exposed to Ultraviolet light energy. Ultraviolet light alters the DNA material in cells so that bacteria, viruses, molds, algae, and other microorganisms can no longer reproduce. The microorganisms are considered dead, and the risk of disease from them is eliminated. These Ultraviolet Disinfection Systems are designed for commercial & industrial applications. The process of UV Disinfection is accomplished without adding any harmful chemicals to your drinking water and does not distort the water or effect its pH value. UV Disinfection has an effective kill rate of 99.99% of most living microorganisms such as bacteria & viruses.
As water flows past the UV lamp(s) in a UV disinfection system, microorganisms are exposed to Ultraviolet light energy. Ultraviolet light alters the DNA material in cells so that bacteria, viruses, molds, algae, and other microorganisms can no longer reproduce. The microorganisms are considered dead, and the risk of disease from them is eliminated. These Ultraviolet Disinfection Systems are designed for commercial & industrial applications. The process of UV Disinfection is accomplished without adding any harmful chemicals to your drinking water and does not distort the water or effect its pH value. UV Disinfection has an effective kill rate of 99.99% of most living microorganisms such as bacteria & viruses.
Effective in killing off bacteria and viruses - UV Disinfection is suitable for Whole-House, Commercial, and Industrial Water Treatment Applications
|
|
Model # PRO 30 UV Bacteria Treatment
- 30gpm Flow Rate: Rated Flow For NSF 55 Class A Certification - YES
- UV Chamber Dimensions: 41" x 4"
- Power Supply Dimensions: 13" x 6.5"
- Voltage: 120/240V./50-60Hz
- Max Current / Power Consumption: 2.4 Amp / 230 Watts
- Lamp Power: 230 Watts
- Min / Max. Operating Pressure: 10 psi / 100 psi
- Ambient Temperature: 36-104 F
- Inlet/Outlet Port Size: 1.25" MNPT / 1" FNPT "combo"
- Number of UV Lamps: 1 - Replace bulb every 2 years or as needed
- Visual “Power On” - YES
- Chamber Material 316L
- Visual Lamp Life Remaining - YES
- Audible Lamp Failure - YES
- Audible Lamp Replacement Reminder - YES
- UV Sensor - YES
- Flow Meter - YES
- Cool Touch Fan - YES
- Operating Parameters: Max Water Hardness (120ppm - 7gpg); Iron (0.3ppm); Manganese (0.05ppm); Max Temperature (104 F); Min Temperature (32 F); Vertical Installation Only. 5 micron sediment prefilter is also recommended. Plumb 2 or more UV system in parallel for higher flow rate applications!
- Includes FREE Separate NSF Certified Sediment 5 Micron Prefilter System: Dimensions: 4.5" dia x 20" ht - 1" plumbing ports - (1) reusable washable 5 micron sediment filter cartridge & steel mounting bracket.
Limited FREE Time Offer: Heavy-Duty PRE water filter designed to filter excessive sediment, grit, and debris. Easily installs before the UV System. Includes 4.5" x 20" NSF Certified Filter Housing w/ 1" Plumbing Ports, Mounting Bracket, Wrench, and (1) NSF Certified Pleated Reusable Washable Sediment Cartridge |